STACK Quick Start Assemblies - Division 3, ICF
    • Dark
      Light
    • PDF

    STACK Quick Start Assemblies - Division 3, ICF

    • Dark
      Light
    • PDF

    Article summary

    Overview
    STACK's Quick Start assemblies for ICF walls are designed for walls using 12"x48" blocks with optional continuous and vertical rebar. Options for 45 and 90 degree corners are available that also deduct standard blocks from that space.


    03 Concrete

    ICF Wall - Linear

    Summary

    There are five wall assemblies for different size blocks - 4", 6", 8", 10", and 12". They are identical except for the block item and amount of concrete calculated since wider blocks have more space inside.

    Variables

    • Wall Height In Feet

    Used to calculate the area of the wall for blocks, continuous rebar and concrete.

    • Vertical Rebar Spacing In Inches

    Used to calculate the vertical rebar item if needed.

    • Vertical Rebar Length In Feet 

    Used to calculate the vertical rebar item if needed.

    Required Items

    These items will be automatically added to your takeoff:

    • 4"/6"/8"/10"/12" ICF Block

    Each assembly will have one of the five block sizes. The count is determined by the area of the wall.

    • Concrete 

    Calculated using the area of the wall and size of block.

    Item Groups

    Groups contain a selection of items to choose if needed:

    • Vertical Rebar

    Calculated using the Linear takeoff total and both vertical rebar variables.

    • Continuous (Horizontal) Rebar

    Calculated by multiplying the Linear takeoff total and the number of 16" courses.

    ICF Wall 45/90 Corners - Count

    Summary

    There are five 45 degree corner assemblies and five 90 degree corner assemblies for different size blocks - 4", 6", 8", 10", 12". They are identical except for the block item and amount of area used to calculate standard block deduction.

    Variables

    • Wall Height In Feet

    Used to calculate the the number of corner blocks and the number of standard block to deduct.

    Required Items 

    *These items will be automatically added to your takeoff.

    • 4"/6"/8"/10"/12" ICF Block 

    Each assembly will have one of the five block sizes. The count is determined by the area of the corner blocks.

    • 4"/6"/8"/10"/12" ICF 45/90 Block

    Calculated using the Count takeoff total and wall height.

    Item Groups

    This assembly contains no item groups.